{"product_id":"hyundai-110kva-three-phase-diesel-generator","title":"Hyundai 110kVA Three Phase Diesel Generator","description":"\u003cdiv id=\"TWO_COLUMN_GRID-AT1NkadHbE\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_two_column_grid-AT1NkadHbE \"\u003e\n      \u003cdiv class=\"page-crafter-div-container\"\u003e\n        \u003ch2 class=\"page-crafter-h2 page_crafter_two_column_heading-AT1NkadHbE page-crafter-element-bottom-spacing\"\u003eLooking for reliable standby power for your facility? Meet the Hyundai 110kVA three-phase diesel generator.\u003c\/h2\u003e\n        \u003cdiv class=\"page_crafter_grid_plain_text-AT1NkadHbE     page-crafter-div-container\"\u003e\n\u003cp\u003eWhen your business relies on consistent three phase power, the Hyundai 110kVA Three Phase Diesel Generator provides a dependable solution you can count on. Built to support demanding commercial and industrial environments, this 110kVA Standby Three Phase Diesel Generator is designed to keep essential systems operating when mains power is unavailable.\u003c\/p\u003e\n\u003cp\u003eThe 110kVA Diesel Generator is well suited to worksites, warehouses, farms, workshops, and larger facilities that run heavy three phase equipment. When an outage occurs, having reliable standby power helps prevent costly downtime and keeps operations moving. This generator delivers the strong and stable output needed to support machinery, tools, and electrical systems that businesses rely on every day.\u003c\/p\u003e\n\u003cp\u003eHyundai generators are known for their durability and solid engineering, and this model is no exception. The powerful diesel engine is designed for long running performance and efficient fuel use. That makes it a practical option for both standby use and longer operating periods when continuous power is required.\u003c\/p\u003e\n\u003cp\u003eThe enclosed generator design helps protect the internal components from harsh outdoor conditions. It also reduces operational noise, making it more suitable for commercial environments where noise control and equipment protection are important considerations.\u003c\/p\u003e\n\u003cp\u003eWith dependable performance and the capability to support demanding electrical loads, the Hyundai 110kVA Three Phase Diesel Generator provides peace of mind for businesses that cannot afford power interruptions. It is a reliable power solution that helps keep your site productive, safe, and operating as it should.\u003c\/p\u003e\n\u003c\/div\u003e\n        \n      \u003c\/div\u003e\n\n      \u003cdiv class=\"page_crafter_grid_media_container-AT1NkadHbE  page-crafter-div-container\"\u003e\n        \u003cimg class=\"page-crafter-image-base-class page_crafter_grid_media-AT1NkadHbE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/Hyundai-110kVA-Three-Phase-Diesel-Generator-1_5d7f959d-8c00-428e-b570-a2815b84fb3a.jpg?v=1772734956\" alt=\"Hyundai 110kVA Three Phase Diesel Generator on a white background.\"\u003e\n      \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"SPACER-ijtmf4XkwC\"\u003e \u003cdiv class=\"page-crafter-block\" style=\"height:20px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv id=\"HEADING-k107x7Blfb\"\u003e\u003ch2 class=\"page-crafter-h2 page_crafter_heading-k107x7Blfb \"\u003eGot heavy three-phase machinery to power? Choose a 110kVA Three Phase Diesel Generator that can handle the load.\u003c\/h2\u003e\u003c\/div\u003e\u003cdiv id=\"TEXT-QBJFIAqkIG\"\u003e\u003cdiv class=\"page_crafter_plain_text-QBJFIAqkIG     page-crafter-div-container\"\u003e\n\u003cp\u003eThis generator is built with a durable, industrial grade diesel engine that is designed to perform under heavy workloads. Diesel engines are known for their strength and efficiency, making them a practical choice for both standby power and longer running applications. Businesses that rely on constant electricity can operate with confidence knowing the generator is designed to handle demanding conditions.\u003c\/p\u003e\n\u003cp\u003eThe enclosed silenced canopy helps keep noise levels under control while protecting the internal components from weather and dust. This makes the generator suitable for a wide range of environments, including construction sites, commercial facilities, and agricultural properties. The enclosed design also helps extend the lifespan of the equipment by shielding key parts from the elements.\u003c\/p\u003e\n\u003cp\u003eAn advanced digital control panel allows operators to easily monitor the generator’s performance. Important information such as output, running status, and system alerts can be checked quickly, making day to day operation straightforward. This helps ensure the generator continues operating efficiently and safely.\u003c\/p\u003e\n\u003cp\u003eThe Hyundai DHY110KSE-3 offers the power capacity businesses need to support demanding equipment and essential operations. Whether it is used as a primary power source on site or as a reliable standby system during outages, this generator helps keep your operation productive and running without interruption.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TWO_COLUMN_GRID-oBHYqVSLU4\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_two_column_grid-oBHYqVSLU4 \"\u003e\n      \u003cdiv class=\"page-crafter-div-container\"\u003e\n        \n        \n        \n      \u003c\/div\u003e\n\n      \u003cdiv class=\"page_crafter_grid_media_container-oBHYqVSLU4  page-crafter-div-container\"\u003e\n        \n      \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"SPACER-8Wa4d86hkO\"\u003e \u003cdiv class=\"page-crafter-block\" style=\"height:20px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv id=\"HEADING-yEeePFkVg5\"\u003e\u003ch2 class=\"page-crafter-h2 page_crafter_heading-yEeePFkVg5 \"\u003eHyundai 110kVA Three Phase Diesel Generator Specifications\u003c\/h2\u003e\u003c\/div\u003e\u003cdiv id=\"TABLE-HvcahshfT9\"\u003e\u003cdiv class=\"page-crafter-simple-table-container page-crafter-div-container\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eMODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eDHY110KSE-3\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eSTANDBY POWER OUTPUT\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e110 kVA \/ 88 kW\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003ePRIME POWER OUTPUT\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e100 kVA \/ 80 kW\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL TANK CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e450 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eDIMENSIONS\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e320 CM \/ 113 CM \/ 185 CM\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eWEIGHT\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e1760 KG\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eSPEED\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e1500 RPM\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eDUTY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eCRITICAL STANDBY \/ LIMITED PRIME\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFREQUENCY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e50Hz\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003ePHASE\/VOLTAGE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eTHREE PHASE \/ 415V\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL TYPE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eDIESEL\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eENGINE MODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eHLR4M3L-DA\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCYLINDER\/ CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e4 CYL \/ 4.75 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eINDUCTION\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eTURBOCHARGED\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL CONSUMPTION\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e25 L\/HR @ 100% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e19.5 L\/HR @ 75% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e13.7 L\/HR @ 50% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eGOVERNOR\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eELECTRONIC\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eOIL CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e14 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCOOLANT CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e28 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"SPACER-qK5IsLUf1Y\"\u003e \u003cdiv class=\"page-crafter-block\" style=\"height:20px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv id=\"HEADING-cTpVSZLgvY\"\u003e\u003ch2 class=\"page-crafter-h2 page_crafter_heading-cTpVSZLgvY \"\u003e110kVA Three Phase Diesel Generator Features\u003c\/h2\u003e\u003c\/div\u003e\u003cdiv id=\"TABLE-DVNXuEoz8f\"\u003e\u003cdiv class=\"page-crafter-simple-table-container page-crafter-div-container\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFEATURES\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eSILENCED CANOPY – 72dB(A) @ 7M\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eHEAVY DUTY SKID BASE WITH FORK POCKETS\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBUNDED FUEL TANK – 23 HOUR RUN TIME @ 75% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBATTERY CHARGER AND ISOLATOR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eOUTLETS – 2 x 32 AMP 415V, 2 x 15 AMP 240V\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCONTROL BRAND AND MODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eDEEPSEA 6120\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCIRCUIT BREAKER\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eFOUR POLE\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eALTERNATOR BRAND AND MODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eHYUNDAI HK274C\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eALTERNATOR TYPE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBRUSHLESS \/ AVR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eHARMONIC DISTORTION\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eLESS THAN 5%\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eINSULATION CLASS\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eCLASS H\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eOPTIONS\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eMINE SPEC\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eJACKET WATER HEATER\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eEXTERNAL FUEL CONNECTION\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eAUTO TRANSFER SWITCHES (ATS)\u003c\/td\u003e\n      \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"SPACER-d89IGIu4H7\"\u003e \u003cdiv class=\"page-crafter-block\" style=\"height:20px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv id=\"HEADING_PARA-UzmJ1GMwdk\"\u003e\u003cdiv class=\"page_crafter_heading_para_container-UzmJ1GMwdk   page-crafter-div-container\"\u003e\n    \u003ch2 class=\"page-crafter-h2 page_crafter_heading-UzmJ1GMwdk page-crafter-element-bottom-spacing\"\u003e110kVA Diesel Generator Important Information\u003c\/h2\u003e  \n  \u003cdiv class=\"page_crafter_para-UzmJ1GMwdk     page-crafter-div-container\"\u003e\n\u003cp\u003eCharging power tool battery packs from a conventional generator is fine. For smoother charging and better results, keep a steady load on the generator and avoid running appliances that cause the load to jump around while the batteries are on charge.\u003c\/p\u003e\n\u003cp\u003eBetween diesel and petrol, diesel generators generally operate at lower temperatures and lower RPM than petrol units. That reduced operating stress can mean less wear and tear, especially when the generator is used often or for longer run times.\u003c\/p\u003e\n\u003cp\u003eUnderloading is a common issue with diesel generators because the engine needs a meaningful load to reach its optimum operating temperature. If it runs too lightly loaded, some fuel may not burn properly, leading to soot build-up. Over time, soot can contribute to cylinder bore glazing, sticking piston rings, reduced compression, and carbon build-up on injectors, which can worsen incomplete combustion.\u003c\/p\u003e\n\u003cp\u003eEarly signs of underloading problems include heavy smoke from the exhaust. If it continues, unburnt fuel can condense in the exhaust and mix with soot to form a thick, dark liquid that can look like an engine oil leak. This can seep from the exhaust and may build up in the exhaust silencer, with a risk of ignition if the generator is later run under full load. Ongoing operation with little or no load can potentially cause permanent engine damage.\u003c\/p\u003e\n\u003cp\u003eTo avoid underloading, size the generator to match the actual requirement without oversizing. If extra capacity has been added for future needs, or the existing installation regularly runs below capacity, a load bank testing program should be used. A load bank creates an artificial demand, typically between 75% and 100% of prime load, which helps burn off carbon deposits and can extend generator life. A common guideline is to run the generator at around 75% of prime power for 2 hours in every 100 hours of use.\u003c\/p\u003e\n\u003cp\u003eFor safety, never run a generator in an attached garage, even with the door open. Position it so exhaust fumes cannot enter the home through windows, doors, or other openings, and make sure the exhaust is directed away from the building.\u003c\/p\u003e\n\u003cp\u003eIf a diesel generator won’t start, the most common causes include battery failure, low coolant levels, an incorrect or poor-quality fuel mix, or the controls not being set to auto.\u003c\/p\u003e\n\u003cp\u003eSome white smoke on start-up can be normal for all but the most modern diesel engines, as long as it clears once the engine warms up. Ongoing smoke after warm-up can indicate another issue that needs attention.\u003c\/p\u003e\n\u003cp\u003ePreventive maintenance should include regular general inspections of coolant level, oil level, the fuel system, and the starting system. Charge-air cooler piping and hoses should also be checked for leaks, holes, cracks, loose connections, and any dirt or debris that may be blocking the fins.\u003c\/p\u003e\n\u003cp\u003eIt’s not recommended to let a generator run completely out of diesel. Running out of fuel can cause the generator’s coils to lose their magnetism, as the appliances being powered can drain residual magnetism when the load stops abruptly.\u003c\/p\u003e\n\u003cp\u003eA diesel generator is made up of several core systems, including the diesel engine, fuel system, voltage regulator, cooling system and exhaust system, lubrication system, battery charger, control panel, and the main assembly frame or skid.\u003c\/p\u003e\n\u003cp\u003eMany diesel generators run at 1500 RPM because the slower engine speed is typically less stressed than higher-speed models. That makes them a strong choice for fixed installations used for daily prime power and standby operation, with well-maintained units often achieving 10,000+ running hours.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TEXT-bWbeO9HgSQ\"\u003e\u003cdiv class=\"page_crafter_plain_text-bWbeO9HgSQ     page-crafter-div-container\"\u003e\n\u003cp\u003e\u003cstrong\u003ePRIME POWER (PRP):\u003c\/strong\u003e Continuous operation at variable load unlimited hours per year, with an average load factor of 75%. 10% overload capability is 1 hour in a 12 hour period of operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTANDBY POWER RATING (ESP): \u003c\/strong\u003eEmergency power supply with an average load factor of 85%. No overload capability. Limited to 400 hours per year.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e    \u003cstyle\u003e.page_crafter_two_column_grid-AT1NkadHbE  { align-items: center;     }  .page_crafter_two_column_heading-AT1NkadHbE { color: #000000;  text-align: left;  font-size: null;    color: #000000 !important; }  .page_crafter_grid_plain_text-AT1NkadHbE  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  .page_crafter_grid_media-AT1NkadHbE { height: null;  width: null;     }  .page_crafter_grid_media_container-AT1NkadHbE  { text-align: null;  order: 1;     }  .page_crafter_two_column_button-AT1NkadHbE  { background-color: #000;  color: #fff;  font-size: 16px;    color: #fff !important; }  #TWO_COLUMN_GRID-AT1NkadHbE {\n    margin-bottom: 20px;  \n  }  #SPACER-ijtmf4XkwC {\n    margin-bottom: 10px;  \n  } .page_crafter_heading-k107x7Blfb { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }  #HEADING-k107x7Blfb {\n    margin-bottom: 10px;  \n  } .page_crafter_plain_text-QBJFIAqkIG  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  #TEXT-QBJFIAqkIG {\n    margin-bottom: 10px;  \n  } .page_crafter_two_column_grid-oBHYqVSLU4  { align-items: center;     }  .page_crafter_two_column_heading-oBHYqVSLU4   { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }  .page_crafter_grid_plain_text-oBHYqVSLU4  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  .page_crafter_grid_media-oBHYqVSLU4   { height: null;  width: null;     }  .page_crafter_grid_media_container-oBHYqVSLU4  { text-align: null;  order: -1;     }  .page_crafter_two_column_button-oBHYqVSLU4  { background-color: #000;  color: #fff;  font-size: 16px;    color: #fff !important; }  #TWO_COLUMN_GRID-oBHYqVSLU4 {\n    margin-bottom: 20px;  \n  }  #SPACER-8Wa4d86hkO {\n    margin-bottom: 10px;  \n  } .page_crafter_heading-yEeePFkVg5 { color: #000;  text-align: center;  font-size: null;    color: #000 !important; }  #HEADING-yEeePFkVg5 {\n    margin-bottom: 10px;  \n  }  #TABLE-HvcahshfT9 {\n    margin-bottom: 10px;  \n  }  #SPACER-qK5IsLUf1Y {\n    margin-bottom: 10px;  \n  } .page_crafter_heading-cTpVSZLgvY { color: #000;  text-align: center;  font-size: null;    color: #000 !important; }  #HEADING-cTpVSZLgvY {\n    margin-bottom: 10px;  \n  }  #TABLE-DVNXuEoz8f {\n    margin-bottom: 10px;  \n  }  #SPACER-d89IGIu4H7 {\n    margin-bottom: 10px;  \n  } .page_crafter_heading_para_container-UzmJ1GMwdk  { text-align: null;     }  .page_crafter_heading-UzmJ1GMwdk { color: #000;  text-align: null;  font-size: null;    color: #000 !important; }  .page_crafter_para-UzmJ1GMwdk  { color: #000;  font-size: ;  text-align: null;    color: #000 !important; }  #HEADING_PARA-UzmJ1GMwdk {\n    margin-bottom: 10px;  \n  } .page_crafter_plain_text-bWbeO9HgSQ  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  #TEXT-bWbeO9HgSQ {\n    margin-bottom: 10px;  \n  }\n  \n  @media (max-width: 798px) {\n          #TWO_COLUMN_GRID-AT1NkadHbE {\n    \n  }  #SPACER-ijtmf4XkwC {\n    \n  }  #HEADING-k107x7Blfb {\n    \n  }  #TEXT-QBJFIAqkIG {\n    \n  }       #TWO_COLUMN_GRID-oBHYqVSLU4 {\n    \n  }  #SPACER-8Wa4d86hkO {\n    \n  }  #HEADING-yEeePFkVg5 {\n    \n  }  #TABLE-HvcahshfT9 {\n    \n  }  #SPACER-qK5IsLUf1Y {\n    \n  }  #HEADING-cTpVSZLgvY {\n    \n  }  #TABLE-DVNXuEoz8f {\n    \n  }  #SPACER-d89IGIu4H7 {\n    \n  }    #HEADING_PARA-UzmJ1GMwdk {\n    \n  }  #TEXT-bWbeO9HgSQ {\n    \n  }\n  }\n  \u003c\/style\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":52727828545903,"sku":"DHY110KSE","price":35138.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/Hyundai-110kVA-Three-Phase-Diesel-Generator-1.jpg?v=1772734514","url":"https:\/\/prestigepower.com.au\/products\/hyundai-110kva-three-phase-diesel-generator","provider":"Prestige Power","version":"1.0","type":"link"}