{"product_id":"hyundai-22kva-single-phase-diesel-generator","title":"Hyundai 22kVA Single Phase Diesel Generator","description":"\u003cdiv id=\"TWO_COLUMN_GRID-AT1NkadHbE\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_two_column_grid-AT1NkadHbE \"\u003e\n      \u003cdiv class=\"page-crafter-div-container\"\u003e\n        \u003ch2 class=\"page-crafter-h2 page_crafter_two_column_heading-AT1NkadHbE page-crafter-element-bottom-spacing\"\u003eTired of power outages disrupting your home or business? Could the Hyundai 22kVA Single Phase Diesel Generator be the dependable generator that finally gives you peace of mind?\u003c\/h2\u003e\n        \u003cdiv class=\"page_crafter_grid_plain_text-AT1NkadHbE     page-crafter-div-container\"\u003e\n\u003cp\u003eThe Hyundai 22kVA Single Phase Diesel Generator is built for people who want dependable, whole-property backup without the stress. This 22kVA Diesel Generator, model 22kVA Hyundai DHY18KSEM, is designed to keep your home or business running when the grid lets you down. Whether it is unexpected outages or planned works, you stay in control with steady, reliable power.\u003c\/p\u003e\n\u003cp\u003eWith a strong 22kVA output, this generator is ideal for larger homes, workshops and small commercial sites that need serious backup capacity. It comfortably runs essential circuits and high-demand equipment, helping you avoid downtime and disruption. That means no scrambling in the dark, no lost productivity, and no worrying about fridges, tools or systems shutting off when you need them most.\u003c\/p\u003e\n\u003c\/div\u003e\n        \n      \u003c\/div\u003e\n\n      \u003cdiv class=\"page_crafter_grid_media_container-AT1NkadHbE  page-crafter-div-container\"\u003e\n        \u003cimg class=\"page-crafter-image-base-class page_crafter_grid_media-AT1NkadHbE\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-1.jpg?v=1771949573\" alt=\"Hyundai 22kVA Single Phase Diesel Generator front view. Generator on a white background.\"\u003e\n      \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TWO_COLUMN_GRID-oBHYqVSLU4\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_two_column_grid-oBHYqVSLU4 \"\u003e\n      \u003cdiv class=\"page-crafter-div-container\"\u003e\n        \u003ch2 class=\"page-crafter-h2 page_crafter_two_column_heading-oBHYqVSLU4   page-crafter-element-bottom-spacing\"\u003eWant to protect your home, office or site from costly downtime? The 22kVA Single Phase Diesel Generator keeps everything running when it matters most.\u003c\/h2\u003e\n        \u003cdiv class=\"page_crafter_grid_plain_text-oBHYqVSLU4     page-crafter-div-container\"\u003e\n\u003cp\u003eAs a single phase diesel generator, the Hyundai 22kVA Single Phase Diesel Generator is suited to most Australian residential and light commercial properties. Diesel power gives you excellent fuel efficiency and long run times, which translates to lower operating costs over time. It is a practical choice for customers who want performance that makes financial sense as well as operational sense.\u003c\/p\u003e\n\u003cp\u003eThe 22kVA Hyundai DHY18KSEM is engineered with durability in mind. Hyundai generators are known for solid build quality and dependable engines that are made to handle regular use. For homeowners with higher expectations and businesses that cannot afford interruptions, this unit delivers the peace of mind that comes from having a robust, ready-to-work backup solution on site.\u003c\/p\u003e\n\u003cp\u003eIf you are looking for a 22kVA Diesel Generator that combines power, efficiency and reliability in one professional package, the Hyundai 22kVA Single Phase Diesel Generator is a smart investment. It gives you confidence that when the power goes out, everything that matters keeps running.\u003c\/p\u003e\n\u003c\/div\u003e\n        \n      \u003c\/div\u003e\n\n      \u003cdiv class=\"page_crafter_grid_media_container-oBHYqVSLU4  page-crafter-div-container\"\u003e\n        \u003cimg class=\"page-crafter-image-base-class page_crafter_grid_media-oBHYqVSLU4  \" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-2.jpg?v=1771949573\" alt=\"Hyundai 22kVA Single Phase Diesel Generator, angular view of the generator showing a side panel door.\"\u003e\n      \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"MEDIA-cGECwMTinB\"\u003e\u003cdiv class=\"page_crafter_media_container_block page_crafter_media_container-cGECwMTinB  page-crafter-div-container\"\u003e\u003cimg class=\"page-crafter-image-base-class page_crafter_media-cGECwMTinB\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-3.jpg?v=1771949573\" alt=\"Hyundai 22kVA Single Phase Diesel Generator . Angular view showing three different doors for generator access.\"\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TWO_COLUMN_SPECS-7r62YXrl3a\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_grid_container-7r62YXrl3a \"\u003e\n    \u003cdiv class=\"page-crafter-div-container\"\u003e\n      \u003ch2 class=\"page-crafter-h2 page_crafter_grid_heading-7r62YXrl3a page-crafter-element-bottom-spacing\"\u003eHyundai 22kVA Single Phase Diesel Generator Specifications\u003c\/h2\u003e\n      \u003cdiv class=\"page-crafter-simple-table-container page-crafter-div-container\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eMODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eDHY18KSEM\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003ePRIME POWER\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e20kVA \/ 16kW\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eSTANDBY POWER OUTPUT Output\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e 22kVA \/ 17.6 kW\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL TANK CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e80 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eDIMENSIONS\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e203.8 CM \/ 85 CM \/112.5 CM\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eWEIGHT (DRY)\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e900 KG\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eSPEED\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e1500 RPM\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eDUTY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eCRITICAL STAND BY \/ LIMITED PRIME\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFREQUENCY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e50 Hz\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003ePHASE\/VOLTAGE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eSINGLE PHASE \/ 240V\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL TYPE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e DIESEL\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eENGINE MODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eH4DW91-29D\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCYLINDER\/ CAPACITY\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e4 CYL \/ 2.54 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eINDUCTION\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eINDUCTION ASPIRATED\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFUEL CONSUMPTION \u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e6 L\/HR @ 100% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e4.6 L\/HR @ 75% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e3.2 L\/HR @ 50% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eGOVERNOR\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eMECHANICAL\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eOIL CAPACITY \u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e8 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCOOLANT CAPACITY \u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e16 LTR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eBRAND AND MODEL\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eDEEP SEA 6120\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eCIRCUIT BREAKER\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eTWO POLE\u003c\/td\u003e\n      \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"page_crafter_grid_media_container-7r62YXrl3a  page-crafter-div-container\"\u003e\n      \u003cimg class=\"page-crafter-image-base-class page_crafter_grid_media-7r62YXrl3a\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-1.jpg?v=1771949573\" alt=\"Hyundai 22kVA Single Phase Diesel Generator front view. Generator on a white background.\"\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TWO_COLUMN_SPECS-IGU1FEj8Bv\"\u003e\u003cdiv class=\"page-crafter-two-column-grid page_crafter_grid_container-IGU1FEj8Bv \"\u003e\n    \u003cdiv class=\"page-crafter-div-container\"\u003e\n      \u003ch2 class=\"page-crafter-h2 page_crafter_grid_heading-IGU1FEj8Bv page-crafter-element-bottom-spacing\"\u003e22kVA Single Phase Diesel Generator Features\u003c\/h2\u003e\n      \u003cdiv class=\"page-crafter-simple-table-container page-crafter-div-container\"\u003e\n    \u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eFEATURES\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eALTERNATOR BRAND AND MODEL \u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eHYUNDAI HK184E\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eALTERNATOR  TYPE\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBRUSHLESS \/ AVR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eHARMONIC DISTORTION \u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eLESS THAN 5%\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eINSULATION CLASS\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eH\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003eOTHER FEATURES\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003e\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eSILENCED CANOPY -67 DB(A) @ 7M\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eHEAVY DUTY SKID BASE WITH FORK LIFT POCKETS\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBUNDED FUEL TANK - 17 HOUR RUN TIME @75% LOAD\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eCANOPY - GALVANISED POWDER COAT\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eBATTERY CHARGER AND ISOLATOR\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eOUTLETS - 1 x 32 AMP 240V, 2 x 15 AMP 240 V\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eAUTO TRANSFER SWITCHES  (ATS)\u003c\/td\u003e\n      \u003c\/tr\u003e \u003ctr\u003e\n        \u003ctd\u003e\n            \u003cstrong\u003e\u003c\/strong\u003e\n          \u003c\/td\u003e \u003ctd\u003eJACKET WATER HEATER\u003c\/td\u003e\n      \u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n  \u003c\/div\u003e\n    \u003c\/div\u003e\n\n    \u003cdiv class=\"page_crafter_grid_media_container-IGU1FEj8Bv  page-crafter-div-container\"\u003e\n      \u003cimg class=\"page-crafter-image-base-class page_crafter_grid_media-IGU1FEj8Bv\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-3.jpg?v=1771949573\" alt=\"Hyundai 22kVA Single Phase Diesel Generator . Angular view showing three different doors for generator access, image on a white background.\"\u003e\n    \u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"TEXT-NbFHtp8i6h\"\u003e\u003cdiv class=\"page_crafter_plain_text-NbFHtp8i6h     page-crafter-div-container\"\u003e\n\u003cp\u003e\u003cstrong\u003ePRIME POWER (PRP)\u003c\/strong\u003e: Continuous operation at variable load unlimited hours per year, with an average load factor of 75%. 10% overload capability is 1 hour in a 12 hour period of operation. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSTANDBY POWER RATING (ESP)\u003c\/strong\u003e: Emergency power supply with an average load factor of 85%. No overload capability. Limited to 400 hours per year\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003cdiv id=\"SPACER-23ugTEK9pt\"\u003e \u003cdiv class=\"page-crafter-block\" style=\"height:20px;\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv id=\"HEADING_PARA-UzmJ1GMwdk\"\u003e\u003cdiv class=\"page_crafter_heading_para_container-UzmJ1GMwdk   page-crafter-div-container\"\u003e\n    \u003ch2 class=\"page-crafter-h2 page_crafter_heading-UzmJ1GMwdk page-crafter-element-bottom-spacing\"\u003e22kVA Single Phase Diesel Generator Important Information\u003c\/h2\u003e  \n  \u003cdiv class=\"page_crafter_para-UzmJ1GMwdk     page-crafter-div-container\"\u003e\n\u003cp\u003eCharging power tool battery packs from a conventional generator is fine. For smoother charging and better results, keep a steady load on the generator and avoid running appliances that cause the load to jump around while the batteries are on charge.\u003c\/p\u003e\n\u003cp\u003eBetween diesel and petrol, diesel generators generally operate at lower temperatures and lower RPM than petrol units. That reduced operating stress can mean less wear and tear, especially when the generator is used often or for longer run times.\u003c\/p\u003e\n\u003cp\u003eUnderloading is a common issue with diesel generators because the engine needs a meaningful load to reach its optimum operating temperature. If it runs too lightly loaded, some fuel may not burn properly, leading to soot build-up. Over time, soot can contribute to cylinder bore glazing, sticking piston rings, reduced compression, and carbon build-up on injectors, which can worsen incomplete combustion.\u003c\/p\u003e\n\u003cp\u003eEarly signs of underloading problems include heavy smoke from the exhaust. If it continues, unburnt fuel can condense in the exhaust and mix with soot to form a thick, dark liquid that can look like an engine oil leak. This can seep from the exhaust and may build up in the exhaust silencer, with a risk of ignition if the generator is later run under full load. Ongoing operation with little or no load can potentially cause permanent engine damage.\u003c\/p\u003e\n\u003cp\u003eTo avoid underloading, size the generator to match the actual requirement without oversizing. If extra capacity has been added for future needs, or the existing installation regularly runs below capacity, a load bank testing program should be used. A load bank creates an artificial demand, typically between 75% and 100% of prime load, which helps burn off carbon deposits and can extend generator life. A common guideline is to run the generator at around 75% of prime power for 2 hours in every 100 hours of use.\u003c\/p\u003e\n\u003cp\u003eFor safety, never run a generator in an attached garage, even with the door open. Position it so exhaust fumes cannot enter the home through windows, doors, or other openings, and make sure the exhaust is directed away from the building.\u003c\/p\u003e\n\u003cp\u003eIf a diesel generator won’t start, the most common causes include battery failure, low coolant levels, an incorrect or poor-quality fuel mix, or the controls not being set to auto.\u003c\/p\u003e\n\u003cp\u003eSome white smoke on start-up can be normal for all but the most modern diesel engines, as long as it clears once the engine warms up. Ongoing smoke after warm-up can indicate another issue that needs attention.\u003c\/p\u003e\n\u003cp\u003ePreventive maintenance should include regular general inspections of coolant level, oil level, the fuel system, and the starting system. Charge-air cooler piping and hoses should also be checked for leaks, holes, cracks, loose connections, and any dirt or debris that may be blocking the fins.\u003c\/p\u003e\n\u003cp\u003eIt’s not recommended to let a generator run completely out of diesel. Running out of fuel can cause the generator’s coils to lose their magnetism, as the appliances being powered can drain residual magnetism when the load stops abruptly.\u003c\/p\u003e\n\u003cp\u003eA diesel generator is made up of several core systems, including the diesel engine, fuel system, voltage regulator, cooling system and exhaust system, lubrication system, battery charger, control panel, and the main assembly frame or skid.\u003c\/p\u003e\n\u003cp\u003eMany diesel generators run at 1500 RPM because the slower engine speed is typically less stressed than higher-speed models. That makes them a strong choice for fixed installations used for daily prime power and standby operation, with well-maintained units often achieving 10,000+ running hours.\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/div\u003e\u003c\/div\u003e    \u003cstyle\u003e.page_crafter_two_column_grid-AT1NkadHbE  { align-items: center;     }  .page_crafter_two_column_heading-AT1NkadHbE { color: #000000;  text-align: left;  font-size: null;    color: #000000 !important; }  .page_crafter_grid_plain_text-AT1NkadHbE  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  .page_crafter_grid_media-AT1NkadHbE { height: null;  width: null;     }  .page_crafter_grid_media_container-AT1NkadHbE  { text-align: null;  order: 1;     }  .page_crafter_two_column_button-AT1NkadHbE  { background-color: #000;  color: #fff;  font-size: 16px;    color: #fff !important; }  #TWO_COLUMN_GRID-AT1NkadHbE {\n    margin-bottom: 20px;  \n  } .page_crafter_two_column_grid-oBHYqVSLU4  { align-items: center;     }  .page_crafter_two_column_heading-oBHYqVSLU4   { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }  .page_crafter_grid_plain_text-oBHYqVSLU4  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  .page_crafter_grid_media-oBHYqVSLU4   { height: null;  width: null;     }  .page_crafter_grid_media_container-oBHYqVSLU4  { text-align: null;  order: -1;     }  .page_crafter_two_column_button-oBHYqVSLU4  { background-color: #000;  color: #fff;  font-size: 16px;    color: #fff !important; }  #TWO_COLUMN_GRID-oBHYqVSLU4 {\n    margin-bottom: 20px;  \n  } .page_crafter_media-cGECwMTinB { height: null;  width: null;     }  .page_crafter_media_container-cGECwMTinB  { text-align: null;     }  #MEDIA-cGECwMTinB {\n    margin-bottom: 10px;  \n  } .page_crafter_grid_container-7r62YXrl3a  { align-items: null;     }  .page_crafter_grid_heading-7r62YXrl3a { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }   .page_crafter_grid_media-7r62YXrl3a { height: null;  width: null;     }  .page_crafter_grid_media_container-7r62YXrl3a  { text-align: null;  order: 1;     }  #TWO_COLUMN_SPECS-7r62YXrl3a {\n    margin-bottom: 20px;  \n  } .page_crafter_grid_container-IGU1FEj8Bv  { align-items: null;     }  .page_crafter_grid_heading-IGU1FEj8Bv { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }   .page_crafter_grid_media-IGU1FEj8Bv { height: null;  width: null;     }  .page_crafter_grid_media_container-IGU1FEj8Bv  { text-align: null;  order: -1;     }  #TWO_COLUMN_SPECS-IGU1FEj8Bv {\n    margin-bottom: 10px;  \n  } .page_crafter_plain_text-NbFHtp8i6h  { color: #000;  font-size: ;  text-align: left;    color: #000 !important; }  #TEXT-NbFHtp8i6h {\n    margin-bottom: 10px;  \n  }  #SPACER-23ugTEK9pt {\n    margin-bottom: 10px;  \n  } .page_crafter_heading_para_container-UzmJ1GMwdk  { text-align: null;     }  .page_crafter_heading-UzmJ1GMwdk { color: #000;  text-align: null;  font-size: null;    color: #000 !important; }  .page_crafter_para-UzmJ1GMwdk  { color: #000;  font-size: ;  text-align: null;    color: #000 !important; }  #HEADING_PARA-UzmJ1GMwdk {\n    margin-bottom: 10px;  \n  }\n  \n  @media (max-width: 798px) {\n          #TWO_COLUMN_GRID-AT1NkadHbE {\n    \n  }       #TWO_COLUMN_GRID-oBHYqVSLU4 {\n    \n  }   #MEDIA-cGECwMTinB {\n    \n  }      #TWO_COLUMN_SPECS-7r62YXrl3a {\n    \n  }      #TWO_COLUMN_SPECS-IGU1FEj8Bv {\n    \n  }  #TEXT-NbFHtp8i6h {\n    \n  }  #SPACER-23ugTEK9pt {\n    \n  }    #HEADING_PARA-UzmJ1GMwdk {\n    \n  }\n  }\n  \u003c\/style\u003e","brand":"Hyundai","offers":[{"title":"Default Title","offer_id":52703096668527,"sku":"DHY18KSEM","price":14800.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0922\/0059\/9919\/files\/HYUNDAI-22kVA-SINGLE-PHASE-DIESEL-GENERATOR-1.jpg?v=1771949573","url":"https:\/\/prestigepower.com.au\/products\/hyundai-22kva-single-phase-diesel-generator","provider":"Prestige Power","version":"1.0","type":"link"}